Set up your components, racking and field design, then generate one or several layout options. Concept scores each option so you can preview them and apply the best one. Concept loads default settings, but you can set your own.
Before you begin
- Define your buildable area. See Run buildable area analysis.
- Create custom components (optional). To evaluate a site with your own components, add them to the PVcase Component Database first.
Step 1: Select a module and inverter
- Click Layout in the left sidebar, then select Components.
- Select a module. To narrow the list, filter by:
- Components your company added, or External components that are DNV verified.
- Manufacturer
- Source: added by your company (internal) or external
- Database tags: approved, obsolete or preferred. Set tags by clicking Manage database.
- You can also search for a component by name.
- Select an inverter the same way.
What you set next depends on your inverter type:
- String inverter: Define a transformer. Concept prefills its width and length from the average size of a transformer with that power. Change the power and the dimensions update. You can edit them at any time.
- Central inverter: Concept takes the width and length from the component database. You can edit them at any time. Define the DC combiners per inverter.
Step 2: Define the racking
- Choose the frame type: fixed tilt or single-axis tracker.
- Choose the module orientation: portrait or landscape.
- Set the Modules per string. Concept shows the recommended value for your module, for example 22 to 26.
- Set the Rows in parallel, for example 2.
Step 3: Set the field design
- Azimuth: 0 faces south, 90 faces west and -90 faces east.
- Corridor gap: Concept prefills it from the width or length of your inverter or transformer, plus clearance for drainage, airflow and walking access for maintenance. You can adjust it. Concept warns you if the gap is smaller than the width of a central inverter or the length of a transformer. Increase the gap to clear the warning.
- Terrain-aware layout: Adapts the layout to the slope of your site using online elevation data. If you export the layout as a DXF and open it in Ground Mount, the slopes show in your design. Turn it off to generate a flat layout.
Step 4: Choose how many layouts to run
- One layout: Enter the ground coverage ratio (GCR) you want.
- Multiple layouts: Run multiple layout options, then enter a minimum GCR, a maximum GCR and an increment. A range of 0.25 to 0.7 with an increment of 0.05 gives a layout for 0.25, 0.3, 0.35 and so on up to 0.7.
- Limit DC capacity (optional): Enter a maximum, for example, 5 MW. Generation stops when it reaches this capacity, so the site isn't filled completely. Toggle it off to remove the limit.
- DC/AC range: Set the minimum and maximum DC/AC ratio. The defaults are 1.1 to 1.4. Depending on your components, you may want a higher or lower range.
Step 5: Save your settings as a preset (optional)
Click Save as new and give the preset a name. Later, edit the settings, for example to change only the module, and choose Update to change the preset or Save as new to keep both. Select a saved preset to reuse it.
Step 6: Generate and review layouts
- Click Generate layout.
- Concept scores each option on:
- The percentage of potentially unconnected frames
- How close the DC/AC ratio is to your selection
- How uniform the DC/AC ratio is across transformers or central inverters
- DC cable voltage drops
- GCR coverage
- Yield efficiency
- Click through the options to preview each layout on the map.
- Select the one you want and click Apply.
LCOE isn't shown until you add your financials. See Financials.
Reading your applied layout
Zoom in to see your frames, central inverters and DC combiners. With a string inverter design, you see transformers and inverters instead.
- Map objects: Show or hide items such as central inverters and DC combiners.
- Zone coloring: Turn it on to see how equipment is connected. Zoom in on a central inverter to see the frames connected to it.
- Frames with slashes: Concept couldn't connect these frames. The DC size shown is lower than the layout's full capacity. An information icon next to DC size tells you how many frames were unable to be connected.
- Summary at the top: Shows the buildable area, whether 3D terrain was used, DC size, AC size, DC/AC ratio, annual yield, GCR, and LCOE.
To try a different design, go back to your presets and change the settings, for example, by switching to a string inverter. Then generate again.